Digital Fiber Sensor FX-100

  • Basic Information

  • Order guide

  • Option

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • Sensing characteristics

  • List of fibers

  • Cautions For Use

Basic Information

Taking fiber sensors to the next level

Order guide

Amplifiers

TypeAppearanceModel No.Emitting elementOutput
Standard
type
 

FX-101 (Note 2)Red LEDNPN open-collector
transistor
FX-101P (Note 2)PNP open-collector
transistor
M8 plug-in
connector type
FX-101-Z (Note 3)NPN open-collector
transistor
FX-101P-Z (Note 3)PNP open-collector
transistor
Cable set
(Note 1)
FX-101-CC2NPN open-collector
transistor
FX-101P-CC2PNP open-collector
transistor
Long
sensing
range
type
 FX-102 (Note 2)NPN open-collector
transistor
FX-102P (Note 2)PNP open-collector
transistor
M8 plug-in
connector type
FX-102-Z (Note 3)NPN open-collector
transistor
FX-102P-Z (Note 3)PNP open-collector
transistor
Cable set
(Note 1)
FX-102-CC2NPN open-collector
transistor
FX-102P-CC2PNP open-collector
transistor

Note :

1)The connector attached cable 2 m 6.562 ft CN-14A-C2 is supplied with the amplifier.

2)Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg. Co., Ltd.
(contact: SPHD-001T-P0.5, housing: PAP-04V-S)

3)Make sure to use the optional M8 connector attached cable CN-24A-C□.

Accessory

CN-14A-C2

(Connector attached cable 2 m6.562 ft)* Only include cable set type

FC-FX-1
(Protection cover)

Option

DesignationModel No.Description
Connector
attached cable
CN-14A-C11 m 3.281 ft0.02 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in
CN-14A-C2 (Note 1)2 m 6.562 ft
CN-14A-C33 m 9.843 ft
CN-14A-C55 m 16.404 ft
Connector
attached cable
(Bending-resistant type)
CN-14A-R-C11 m 3.281 ft
CN-14A-R-C22 m 6.562 ft
CN-14A-R-C33 m 9.843 ft
CN-14A-R-C55 m 16.404 ft
M8 connector
attached cable
CN-24A-C22 m 6.562 ftFor M8 plug-in connector type The connector on one end Cable outer diameter: ø4 mm ø0.157 in
CN-24A-C55 m 16.404 ft
ConnectorCN-14ASet of 10 housings and 40 contacts
Amplifier
mounting bracket
MS-DIN-4Mounting bracket for amplifier
End platesMS-DIN-E
2 pcs. per set
When an amplifier moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides.

Note : The connector attached cable CN-14A-C2 is supplied with the cable set type FX-10□-CC2.

M8 connector attached cable

CN-24A-C□

Amplifier mounting bracket

MS-DIN-4

Connector attached cable

CN-14A(-R)-C□

Connector

CN-14A

Recommended connector

Contact:
SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)

Note:
Contact the manufacturer for details of the recommended products.

Recommended crimping tool

Model No.:
YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.)

Note:
Contact the manufacturer for details of the recommended products.

Recommended e-CON connector

Manufactured by 3M Japan Limited
Adapted connector : 37104-3122-000 FL

Please refer to "Introducing the 3M™ mini-clamp connector" for details.

Specifications

TypeStandard typeLong sensing range type
 Cable set Cable set
Model
No.
NPN outputFX-101(-Z)
(Note 5)
FX-101-CC2FX-102(-Z)
(Note 5)
FX-102-CC2
PNP outputFX-101P(-Z)
(Note 5)
FX-101P-CC2FX-102P(-Z)
(Note 5)
FX-102P-CC2
Applicable regulations and certificationsCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification
Supply voltage12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumptionNormal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 100 mA sink current)

<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less (at 100 mA source current)
 Output operationSelectable either Light-ON or Dark-ON, at SET mode
Short-circuit
protection
Incorporated
External input<NPN output type>
NPN non-contact input
• Signal condition
High: +8 V to +V DC or Open
Low: 0 to +2 V DC
(Source current 0.5 mA or less)
• Input impedance: 10 kΩ approx.

<PNP output type>
PNP non-contact input
• Signal condition
High: +4 V to +V DC (Sink current 0.5 to 3 mA)
Low: 0 to +0.6 V DC or Open
• Input impedance: 10 kΩ approx.
Response timeEmission frequency 0: 250 μs or less (factory default setting)
Emission frequency 1: 450 μs or less
Emission frequency 2: 500 μs or less
Emission frequency 3: 600 μs or less
Emission frequency 1: 2.5 ms or less (factory default setting)
Emission frequency 2: 2.8 ms or less
Emission frequency 3: 3.2 ms or less
Emission frequency 4: 5.0 ms or less
Sensitivity setting2-point teaching / Limit teaching / Full-auto teaching
Operation indicatorOrange LED (lights up when the output is ON)
Digital display4 digits (green) + 4 digits (red) LCD display
Fine sensitivity
adjustment function
Incorporated
Timer functionON-delay / OFF-delay timer, switchable either effective or ineffective
[Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms]
Emission amount setting function3-level + Auto setting
Interference prevention
function
Incorporated
Emission frequency selection method (Note 2)
(Functions at emission frequency 1, 2 or 3)
Incorporated
Emission frequency selection method (Note 2)
(Functions at emission frequency 1, 2, 3 or 4)
Ambient
temperature
–10 to +55 ℃ +14 to +131
(If 4 to 7 units are mounted close together: –10 to +50 ℃ +14 to +122 , if 8 to 16 units are mounted close together: –10 to +45 ℃ +14 to +113 ) (No dew condensation or icing allowed),
Storage: –20 to +70 ℃ –4 to +158
Ambient
humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient
illuminance
Incandescent light: 3,000 ℓx or less at the light-receiving face
Voltage
withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3)
Insulation
resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3)
Vibration
resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock
resistance
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Emitting element
(modulated)
Red LED (Peak emission wavelength: 643 nm 0.025 mil)
MaterialEnclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT
Connecting methodConnector (Note 4)
Cable lengthTotal length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
WeightNet weight: 15 g approx.
Gross weight: 35 g approx.
Net weight: 15 g approx.
Gross weight: 75 g approx.
Net weight: 15 g approx.
Gross weight: 35 g approx.
Net weight: 15 g approx.
Gross weight: 75 g approx.
AccessoryFC-FX-1
(Protection cover): 1 pc.
FC-FX-1
(Protection cover): 1 pc.
CN-14A-C2
(Connector attached cable, 2 m 6.562 ft long): 1 pc.
FC-FX-1
(Protection cover): 1 pc.
FC-FX-1
(Protection cover): 1 pc.
CN-14A-C2
(Connector attached cable, 2 m 6.562 ft long): 1 pc.

Notes:

1):Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

2):When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to different frequency values.
However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2.

3):The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.

4):Connector attached cable CN-14A-C2 is not attached to the models that have no "-CC2" at the end of the model Nos.
Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd.
(contact: SPHD-001T-P0.5, housing: PAP-04V-S).

5):Model Nos. having the suffix "-Z" are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C□.

Dimensions

  • Unit: mm in

FX-101□
FX-102□

Amplifier

FX-101□ FX-102□

FX-101(P)-Z
FX-102(P)-Z

Amplifier

FX-101(P)-Z FX-102(P)-Z

CN-14A-C□
CN-14A-R-C□

Connector attached cable (Optional, CN-14A-C2 is attached to FX-101(P)-CC2 / FX-102(P)-CC2)

CN-14A-C□ CN-14A-R-C□

• Length L

Model No.Length L
CN-14A(-R)-C11,000 39.370
CN-14A(-R)-C22,000 78.740
CN-14A(-R)-C33,000 118.110
CN-14A(-R)-C55,000 196.850

MS-DIN-4

Amplifer mounting bracket (Optional)

MS-DIN-4

Material:PBT

MS-DIN-E

End plate (Optional)

MS-DIN-E

Material:Polycarbonate

I/O Circuit and Wiring diagrams

NPN output type

FX-10□(-Z/-CC2)

I/O circuit diagram

NPN output type FX-10□(-Z/-CC2) I/O circuit diagram

Symbols・・・

D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor

Terminal arrangement diagram


Connector type

NPN output type FX-10□(-Z/-CC2) Terminal arrangement diagram Connector type

Terminal No.Function
1+V
2Output
3External input
40 V

M8 plug-in connector type

NPN output type FX-10□(-Z/-CC2) Terminal arrangement diagram M8 plug-in connector type

Terminal No.Function
1+V
2Output
3External input
40 V

PNP output type

FX-10□P(-Z/-CC2)

I/O circuit diagram

PNP output type FX-10□P(-Z/-CC2) I/O circuit diagram

Symbols・・・

D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor

Terminal arrangement diagram


Connector type

PNP output type FX-10□P(-Z/-CC2) Terminal arrangement diagram Connector type

Terminal No.Function
1+V
2Output
3External input
40 V

M8 plug-in connector type

PNP output type FX-10□P(-Z/-CC2) Terminal arrangement diagram M8 plug-in connector type

Terminal No.Function
1+V
2Output
3External input
40 V

Sensing characteristics

Sensing characteristics can be downloaded at catalog download site.
Please contact our office if not listed here.

List of fibers

Fiber List

Square Head Fiber

■Thru-beam type(one pair set)

TypeModel
No.
Sensing range(mm) (Note1)
FX-101

FX-102

Square
head
M3FT-R31100340
M4FT-R43210640
FT-R41W250710
FT-R42W5102,000
FT-R44Y210640
M6FT-R60Y6901,890

■Reflective type

TypeModel
No.
Sensing range(mm) (Note1)(Note2)
FX-101

FX-102

Square
head
M3FD-R31G45150
FD-R32EG2068
FD-R33EG722
FD-R34EG1760
M4FD-R4160170
M6FD-R61Y85185

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Square Head Fiber, refer to product information page.
>>Go to "Square Head Fiber"

Super Quality

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm)
FX-101

FX-102

ThreadedM3FT-30135400
M4FT-40320870
Cylindricalø1.5FT-S20135400
ø3FT-S30320870

■Reflective type

TypeModel No.Sensing range (mm) (Note)
FX-101

FX-102

ThreadedM3FD-3045155
M4FD-4045155
M6FD-60140420
Cylindricalø3FD-S3045155

Note:The sensing range is specified for white non-glossy paper.

For details of Super Quality Fiber, refer to product information page.
>>Go to "Super Quality Fiber"

Threaded Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
FX-101FX-102
ThreadedM3FT-321,3003,600 (Note 2)
FT-31130340
FT-31W80240
M4 FT-43350970
FT-42300800
FT-42W260720
FT-45X340920
ElbowFT-R40270740
M14Long rangeFT-14014,00019,600 (Note 2)

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
ThreadedM3 FD-34G2990
FD-3135140
FD-31W1560
FD-32G70190
FD-32GX75210
Ultra-small diameterFD-EG302070
FD-EG31725
M4FD-4135140
FD-41W80230
FD-42G70190
FD-42GW45140
M6 FD-62170450
FD-61120410
FD-61W80230
FD-61G120350
FD-64X75220
ElbowFD-R60110240

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Threaded Type Fiber, refer to product information page.
>>Go to "Threaded Type Fiber"

Cylindrical Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note)
FX-101

FX-102

Cylindricalø1FT-S114090
ø1.5FT-S22230560
FT-S21130340
FT-S21W80240
ø2.5FT-S321,1003,000
ø3FT-S31W260720
Ultra-small diameterø3FT-E13619
FT-E232280
Side-viewø4FT-V401,0003,100

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
Cylindricalø1.5FD-S21
(Discontinued products)
2570
FD-S231750
ø3FD-S34G2990
FD-S32120345
FD-S32W80230
FD-S3135140
FD-S33GW45140
Ultra-small diameterø1.5FD-E13515
ø3FD-E232070

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Cylindrical Type Fiber, refer to product information page.
>>Go to "Cylindrical Type Fiber"

Sleeve

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
ThreadedM3FT-31S130340
M4FT-42S300800
CylindricalUltra-small diameterø3FT-E13619
FT-E232280
Side-viewø2FT-V23160400
FT-V2595260
FT-V24W3590
ø2.5FT-V30180480

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
ThreadedUltra-small diameterM3FD-EG30S2070
M4FD-41S35140
FD-41SW1560
M6FD-61S130360
CylindricalUltra-small diameterø1.5FD-E13515
ø3FD-E232070
Side-viewø3FD-V302575
FD-V30W620
ø5FD-V5040100

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Sleeve Fiber, refer to product information page.
>>Go to "Sleeve Fiber"

Flat Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note)
FX-101FX-102
Flat FT-Z30H1,4003,200
FT-Z30HW1,4003,200
FT-Z30E1,2003,200
FT-Z30EW1,4002,600
FT-Z307102,300
FT-Z30W5401,800
With bossFT-Z20W280730
FT-Z20HBW100320
FT-Z40W4101,200
FT-Z40HBW260720

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
FlatWith bossFD-Z20W2 to 321 to 80
FD-Z20HBW2 to 301 to 90
FD-Z40W1 to 74200
FD-Z40HBW1 to 900.5 to 240

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Flat Type Fiber, refer to product information page.
>>Go to "Flat Type Fiber"

Narrow Beam

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
FX-101FX-102
Narrow beamFT-KS402,2003,600 (Note 2)
FT-KV402,2003,600 (Note 2)
FT-KV40W2,2003,600 (Note 2)
FT-KV26135560
FT-KV26H1160500

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Retroreflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
With polarizing filtersFR-Z50HW100 to 550100 to 830
Wafer mappingFR-KZ22E15 to 20015 to 360
Narrow beamTop sensingFR-KZ50H20 to 20020 to 350
Side sensingFR-KZ50E20 to 20020 to 350

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

■Reflective type

TypeModel No.Sensing range (mm) (Note)
FX-101FX-102
Long rangeFD-Z50HW10 to 20010 to 530

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Narrow Beam Fiber, refer to product information page.
>>Go to "Narrow Beam Fiber"

Wide Beam

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
FX-101FX-102
Wide beamFT-A323,600 (Note 2)3,600 (Note 2)
FT-A32W3,600 (Note 2)3,600 (Note 2)
FT-A111,9003,600 (Note 2)
FT-A11W1,7003,400
ArrayFT-AL05250660

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range to 3,600 mm long.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
Wide beamFD-A16120240
ArrayFD-AL11
(Discontinued products)
100285
FD-AL1280240

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Wide Beam Fiber, refer to product information page.
>>Go to "Wide Beam Fiber"

Convergent Reflective Type

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
Glass substrate detectionFD-L32H16 to 300 to 50
FD-L30A0 to 400 to 50
FD-L31A5 to 304 to 33
FD-L22A
(Discontinued products)
0 to 190 to 25
FD-L24A0 to 190 to 21
FD-L23
(Discontinued products)
0 to 280 to 30
FD-L250 to 250 to 30
FD-L110 to 80 to 9
FD-L100 to 4.50 to 5.5
FD-L213 to 151.5 to 16
FD-L21W7 to 123 to 14
General purposeFD-L20H5 to 151 to 30
Ultla smallFD-L12W1 to 4.50.5 to 7

Note 1:The sensing range is specified for transparent glass 100 x 100 x t0.7 mm (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm).

Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Convergent Reflective Type Fiber, refer to product information page.
>>Go to "Convergent Reflective Type Fiber"

Retroreflective Type

■Retroreflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
With polarizing filtersFR-Z50HW100 to 550100 to 830
Wafer mappingFR-KZ22E15 to 20015 to 360
Narrow beamTop sensingFR-KZ50H20 to 20020 to 350
Side sensingFR-KZ50E20 to 20020 to 350

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

For details of Retroreflective Type Fiber, refer to product information page.
>>Go to "Retroreflective Type Fiber"

Chemical-resistant

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note)
FX-101FX-102
Chemical-resistantFT-Z802Y5203,100
FT-HL80Y9902,340
FT-L80Y1,1002,600
FT-V80Y340800

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeModel No.Sensing range (mm) (Note1)(Note2)
FX-101

FX-102

Chemical-resistantFD-S60Y140300

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Chemical-resistant Fiber, refer to product information page.
>>Go to "Chemical-resistant Fiber"

Heat-resistant

■Thru-beam type (one pair set)

TypeHeat-resistant temp.Model No.Sensing range (mm) (Note)
FX-101FX-102
Heat-resistant350℃FT-H35-M2170490
FT-H35-M2S6170490
200℃FT-H20W-M1100300
FT-H20-M1210540
130℃FT-H13-FM2250700
Heat-resistant (joint)200℃FT-H20-J20-S135420
FT-H20-J30-S135420
FT-H20-J50-S135420
FT-H20-VJ50-S150500
FT-H20-VJ80-S150500

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeHeat-resistant temp.Model No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
Heat-resistantThreaded350℃FD-H35-M275280
FD-H35-M2S675280
FD-H35-20S85200
200℃FD-H20-M1120300
FD-H20-2190280
130℃FD-H13-FM2100280
Glass substrate detection convergent reflective300℃FD-H30-L322 to 90 to 17
250℃FD-H25-L434 to 164 to 23
FD-H25-L457 to 357 to 38
180℃FD-H18-L310 to 100 to 25

Note 1:The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm glass substrate for FD-H30-L32,
FD-H18-L31, transparent glass 100 x 100 x t0.7 mm for FD-H25-L43 and FD-H25-L45).

Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Heat-resistant Fiber, refer to product information page.
>>Go to "Heat-resistant Fiber"

One-Touch Connection System Vacuum-resistant Fibers

■Thru-beam type

TypeModel No.Sensing range (mm)(Note 1)
FX-101FX-102
Vacuum-
resistant
Thru-beamFT-40V110280

(Note 1):Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeModel No.Sensing range(mm) (Note 1)(Note 2)
FX-101FX-102
Vacuum-
resistant
Long range
reflective
FD-KZ50V25 to 8010 to 220
Convergent
reflective
FD-L10V2.5 to 6.50 to 11

(Note 1):The sensing range is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in.

(Note 2):Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of One-Touch Connection System Vacuum-resistant Fibers, refer to product information page.
>>Go to "One-Touch Connection System Vacuum-resistant Fibers"

Vacuum-resistant

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm)
FX-101FX-102
Vacuum-resistantThru-beamFT-H30-M1V-S110280

■Reflective type

TypeModel No.Sensing range (mm) (Note)
FX-101FX-102
Vacuum-resistantReflectiveFD-H30-KZ1V-S25 to 8010 to 220
Convergent reflectiveFD-H30-L32V-S2.5 to 6.50 to 11

Note:The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm.

For details of Vacuum-resistant Fiber, refer to product information page.
>>Go to "Vacuum-resistant Fiber"

Special-shaped fiber

Special-shaped fiber

Model No.Sensing range (mm)
FX-101FX-102
Heat-resistant U-shaped typeFT-PK40H15(fixed))5(fixed))

Note: Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Special-shaped fiber, refer to product information page.
>>Go to "Special-shaped fiber"

Metal-free

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note)
FX-101FX-102
ThreadedM4FT-41300800

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
FX-101FX-102
ThreadedM4FD-G4050120
M6FD-G60100410

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Metal-free Fiber, refer to product information page.
>>Go to "Metal-free Fiber"

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Using in combination with the FX-300 / FX-410 series

  • The FX-100 series does not use the horizontal connectors that are used with the FX-300 / FX-410 series. Please note that horizontal connection cannot be performed using a connector attached cable. In addition, the optical communication function is not equipped on the FX-100 series, so it is unable to perform interference prevention for use with the FX-300 / FX-410 series.
    If using the FX-100 series together with the FX-300 / FX-410 series side-by-side, please set the same models together in groups.

Mounting

<When using a DIN rail>

How to mount the amplifier

[1]Fit the rear part of the mounting section of the amplifier on a 35 mm 1.378 in width DIN rail.

[2]Press down the rear part of the mounting section of the unit on the 35 mm 1.378 in width DIN rail and fit the front part of the mounting section to the DIN rail.

Mounting When using a DIN rail How to mount the amplifier

How to remove the amplifier

[1]Push the amplifier forward.

[2]Lift up the front part of the amplifier to remove it.

Mounting When using a DIN rail How to remove the amplifier

Note:Take care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break.

<When using screws with washers>

  • Use M3 screws with washers for mounting. The tightening torque should be 0.5 N·m or less.

Mounting When using screws with washers

Wiring

  • Make sure that the power supply is OFF while adding or removing the amplifiers.
  • Note that if a voltage exceeding the reted range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged.
  • Note that short-circuit of the load or wrong wiring may burn or damage the product.
  • Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction.
  • Verify that the supply voltage variation is within the rating.
  • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
  • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
  • Make sure to use the quick-connection cable (optional) for the connection of the controller.
    Extension up to total 100 m 328.084 ft is possible with 0.3 mm2 or more, cable. However, in order to reduce noise, make the wiring as short as possible.

Part description

Part description

Setting mode

  • Setting mode appears after the MODE key is pressed for 2 sec. in RUN mode.
Setting itemFactory settingDescription
Teaching mode

Threshold value can be set in 2-point teaching, limit teaching, or full-auto teaching.
Output operation setting


[Dark-ON]
Light-ON or Dark-ON can be set.
Timer operation setting


[Without timer]
Without timer, ON delay timer, or OFF delay timer can be set.
Timer delays setting


[ON-delay timer: 10 ms]


[OFF-delay timer: 10 ms]
When setting ON delay timer or OFF delay timer in the timer operation setting mode, timer delays can be set.
・When timer is not set, this mode is not displayed.
Emission amount setting


*[Level 3]
In case incident light intensity is saturated, emission amount can be reduced.
Emission frequency settingFX-101


[0 (Response time:250 μs or less)]
FX-102


[1 (Response time:2.5 ms or less)]
When using the fiber heads in parallel, interference can be prevented by setting different emission frequency. However, when emission frequency 0 is set, interference cannot be prevented. Response time corresponds to emission frequency.

PRO mode

  • PRO mode appears after the MODE key is pressed for 4 sec. in RUN mode.
Setting itemFactory settingDescription
Shift setting
[Shift amount 15 %]
Shift amount can be selected from 0 to 80 % in the limit teaching. Select 0 % when it is desired to set the present incident light intensity as a threshold value.
External input setting
[Emission halt]
External input can be selected from emission halt, limit teaching [+], limit teaching [-], full-auto teaching, ECO (Note 1), 2-point teaching or emission amount test. When setting the incident light intensity test “”, output turns ON / OFF every 100ms when the rate of incident light intensity and threshold value is less than half of the set shift amount (for example, when the rate of incident light intensity and threshold value is within ±10 % for 20 % of shift amount) at external input.
Threshold value-storing setting mode (Note 2)Threshold value set at the limit teaching, full-auto teaching or 2-point teaching by external input is stored. When selecting Auto in the emission amount setting mode, the set emission amount level is also stored.
Threshold value follow-up cycle setting (Note 3)When incident light intensity exceeds threshold value, this mode can change the threshold value with each set cycle depending on variations of the incident light intensity. The follow-up shift amount is same as the one set in the shift setting mode. However, the threshold value is not stored.
GETA function setting (Note 4, 5)Variations can be reduced by correcting the present incident light intensity in each amplifier to a target value. Target value to offset incident light intensity can be selected from 0 to 2,000 by 100 unit each. For example, if the target value is set to 2,000 when the incident light intensity is 1,500, the incident light intensity becomes 2,000.
ECO settingIt is possible to light up / turn off the digital display. When ECO setting mode is ON, the display turns off in 20 sec. approx. in RUN mode. To light up the display again, press any key for 2 sec. or more.
Digital display inversion settingDigital display can be inverted.
Threshold value margin settingMargin for threshold value to the present incident light intensity can be checked. When there is no margin, it is possible to make the digital display blink.
: Set to “OFF”: does not function
: Green blinks.
: Red blinks.
: Red and green blink.
: When conducting limit teaching or 2-point teaching by external input, in case the rate of reference incident light intensity and threshold value after teaching is 200% or more, or in case it is less than half of the shift amount, output turns ON / OFF every 100 ms. (Note 6)
Setting copyThe settings of the master side amplifier can be copied to the slave side amplifier.
For details, refer to “Setting copy function”.
ResetReturns to default settings (factory settings.)

PRO mode Notes

Setting copy function

Refer to the "Instruction Manual" for details.

Others

  • This product has been developed / produced for industrial use only.
  • Do not use during the initial transient time (0.5 sec.) after the power supply is switched on.
  • Take care that the product is not directly exposed to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing performance.
  • This product is suitable for indoor use only.
  • Avoid dust, dirt, and steam.
  • Take care that the product does not come in contact with oil, grease, organic solvents, such as thinner, etc., strong acid or alkaline.
  • This product cannot be used in an environment containing inflammable or explosive gases.
  • Never disassemble or modify this product.
  • EEPROM is adopted to this product. It is not possible to conduct teaching 100 thousand times or more, because of the EEPROM’s lifetime.

Quick setting function

Quick setting function

Note:The emission amount of Level 2 (ON) is about 40% of that of Level 3 (OFF).

Code setting function

Code setting function

MENU

Recently checked products

Recently checked product numbers